{"id":4570,"date":"2014-09-08T12:36:44","date_gmt":"2014-09-08T10:36:44","guid":{"rendered":"https:\/\/asso.graie.org\/portail\/?p=4570"},"modified":"2025-12-08T08:58:00","modified_gmt":"2025-12-08T07:58:00","slug":"fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique","status":"publish","type":"post","link":"https:\/\/asso.graie.org\/portail\/fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique\/","title":{"rendered":"Fiche Technique Autosurveillance n\u00b08 : Mesurage d&rsquo;un d\u00e9bit en conduite pleine par un d\u00e9bitm\u00e8tre \u00e9lectromagn\u00e9tique"},"content":{"rendered":"<div>\n<div>Pr\u00e9conis\u00e9 pour les installations en charge permanente (Exple : siphons, postes de refoulement et rel\u00e8vement), les d\u00e9bitm\u00e8tres \u00e9lectromagn\u00e9tiques sont pr\u00e9sent\u00e9s au sein de cette fiche .<\/div>\n<div><em>Elle pr\u00e9cise : le PRINCIPE DE FONCTIONNEMENT \/les CRIT\u00c8RES DE CHOIX \/l&rsquo; INSTALLATION \/la MAINTENANCE \/ la V\u00c9RIFICATION et R\u00c9GLAGE pour ce type de technologie .<\/em><\/div>\n<\/div>\n<div><\/div>\n<div>RAPPEL : L&rsquo;objectif des fiches techniques du groupe de travail autosurveillance est de capitaliser des retours d\u2019exp\u00e9rience notamment sur des technologies de mesure, de fa\u00e7on synth\u00e9tique et pragmatique pour aider les collectivit\u00e9s \u00e0 mettre en \u0153uvre l&rsquo;autosurveillance de leur syst\u00e8me d&rsquo;assainissement .<\/div>\n<div><\/div>\n<a href=\"http:\/\/www.graie.org\/graie\/graiedoc\/reseaux\/autosurv\/FT8_Electromagnetique_vf.pdf\" target=\"_blank\" class=\"shortc-button big blue \"><span class=\"fa fa-file-pdf-o\" aria-hidden=\"true\"><\/span> Outil (2p)<\/a>\n","protected":false},"excerpt":{"rendered":"<p>Pr\u00e9conis\u00e9 pour les installations en charge permanente (Exple : siphons, postes de refoulement et rel\u00e8vement), les d\u00e9bitm\u00e8tres \u00e9lectromagn\u00e9tiques sont pr\u00e9sent\u00e9s au sein de cette fiche . Elle pr\u00e9cise : le PRINCIPE DE FONCTIONNEMENT \/les CRIT\u00c8RES DE CHOIX \/l&rsquo; INSTALLATION \/la &hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_mi_skip_tracking":false,"footnotes":""},"categories":[38,29],"tags":[184,754,753,238,724],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.13 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Fiche Technique Autosurveillance n\u00b08 : Mesurage d&#039;un d\u00e9bit en conduite pleine par un d\u00e9bitm\u00e8tre \u00e9lectromagn\u00e9tique | Graie<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/asso.graie.org\/portail\/fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Fiche Technique Autosurveillance n\u00b08 : Mesurage d&#039;un d\u00e9bit en conduite pleine par un d\u00e9bitm\u00e8tre \u00e9lectromagn\u00e9tique | Graie\" \/>\n<meta property=\"og:description\" content=\"Pr\u00e9conis\u00e9 pour les installations en charge permanente (Exple : siphons, postes de refoulement et rel\u00e8vement), les d\u00e9bitm\u00e8tres \u00e9lectromagn\u00e9tiques sont pr\u00e9sent\u00e9s au sein de cette fiche . Elle pr\u00e9cise : le PRINCIPE DE FONCTIONNEMENT \/les CRIT\u00c8RES DE CHOIX \/l&rsquo; INSTALLATION \/la &hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/asso.graie.org\/portail\/fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique\/\" \/>\n<meta property=\"og:site_name\" content=\"Graie\" \/>\n<meta property=\"article:published_time\" content=\"2014-09-08T10:36:44+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-08T07:58:00+00:00\" \/>\n<meta name=\"author\" content=\"adriengervet\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@asso_graie\" \/>\n<meta name=\"twitter:site\" content=\"@asso_graie\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"adriengervet\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/asso.graie.org\/portail\/fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/asso.graie.org\/portail\/fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique\/\"},\"author\":{\"name\":\"adriengervet\",\"@id\":\"https:\/\/asso.graie.org\/portail\/#\/schema\/person\/6c6bb5a38c33b4501e4e8ce71aba5a8c\"},\"headline\":\"Fiche Technique Autosurveillance n\u00b08 : Mesurage d&rsquo;un d\u00e9bit en conduite pleine par un d\u00e9bitm\u00e8tre \u00e9lectromagn\u00e9tique\",\"datePublished\":\"2014-09-08T10:36:44+00:00\",\"dateModified\":\"2025-12-08T07:58:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/asso.graie.org\/portail\/fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique\/\"},\"wordCount\":148,\"publisher\":{\"@id\":\"https:\/\/asso.graie.org\/portail\/#organization\"},\"keywords\":[\"autosurveillance\",\"conduite\",\"d\u00e9bitm\u00e8tre\",\"m\u00e9trologie\",\"r\u00e9seaux assainissement\"],\"articleSection\":[\"Autosurveillance\",\"Productions\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/asso.graie.org\/portail\/fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique\/\",\"url\":\"https:\/\/asso.graie.org\/portail\/fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique\/\",\"name\":\"Fiche Technique Autosurveillance n\u00b08 : Mesurage d'un d\u00e9bit en conduite pleine par un d\u00e9bitm\u00e8tre \u00e9lectromagn\u00e9tique | Graie\",\"isPartOf\":{\"@id\":\"https:\/\/asso.graie.org\/portail\/#website\"},\"datePublished\":\"2014-09-08T10:36:44+00:00\",\"dateModified\":\"2025-12-08T07:58:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/asso.graie.org\/portail\/fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/asso.graie.org\/portail\/fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/asso.graie.org\/portail\/fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/asso.graie.org\/portail\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Fiche Technique Autosurveillance n\u00b08 : Mesurage d&rsquo;un d\u00e9bit en conduite pleine par un d\u00e9bitm\u00e8tre \u00e9lectromagn\u00e9tique\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/asso.graie.org\/portail\/#website\",\"url\":\"https:\/\/asso.graie.org\/portail\/\",\"name\":\"Graie\",\"description\":\"P\u00f4le Eau et Territoires\",\"publisher\":{\"@id\":\"https:\/\/asso.graie.org\/portail\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/asso.graie.org\/portail\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/asso.graie.org\/portail\/#organization\",\"name\":\"Le Graie\",\"url\":\"https:\/\/asso.graie.org\/portail\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/asso.graie.org\/portail\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/asso.graie.org\/portail\/wp-content\/uploads\/2021\/12\/Logotype-Graie.png\",\"contentUrl\":\"https:\/\/asso.graie.org\/portail\/wp-content\/uploads\/2021\/12\/Logotype-Graie.png\",\"width\":1890,\"height\":1181,\"caption\":\"Le Graie\"},\"image\":{\"@id\":\"https:\/\/asso.graie.org\/portail\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/fr.linkedin.com\/company\/graie?trk=top_nav_home\",\"https:\/\/www.youtube.com\/channel\/UCZQk0Tt7upYwERYNdDIZqLQ\",\"https:\/\/twitter.com\/asso_graie\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/asso.graie.org\/portail\/#\/schema\/person\/6c6bb5a38c33b4501e4e8ce71aba5a8c\",\"name\":\"adriengervet\",\"url\":\"https:\/\/asso.graie.org\/portail\/author\/adriengervet\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Fiche Technique Autosurveillance n\u00b08 : Mesurage d'un d\u00e9bit en conduite pleine par un d\u00e9bitm\u00e8tre \u00e9lectromagn\u00e9tique | Graie","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/asso.graie.org\/portail\/fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique\/","og_locale":"fr_FR","og_type":"article","og_title":"Fiche Technique Autosurveillance n\u00b08 : Mesurage d'un d\u00e9bit en conduite pleine par un d\u00e9bitm\u00e8tre \u00e9lectromagn\u00e9tique | Graie","og_description":"Pr\u00e9conis\u00e9 pour les installations en charge permanente (Exple : siphons, postes de refoulement et rel\u00e8vement), les d\u00e9bitm\u00e8tres \u00e9lectromagn\u00e9tiques sont pr\u00e9sent\u00e9s au sein de cette fiche . Elle pr\u00e9cise : le PRINCIPE DE FONCTIONNEMENT \/les CRIT\u00c8RES DE CHOIX \/l&rsquo; INSTALLATION \/la &hellip;","og_url":"https:\/\/asso.graie.org\/portail\/fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique\/","og_site_name":"Graie","article_published_time":"2014-09-08T10:36:44+00:00","article_modified_time":"2025-12-08T07:58:00+00:00","author":"adriengervet","twitter_card":"summary_large_image","twitter_creator":"@asso_graie","twitter_site":"@asso_graie","twitter_misc":{"\u00c9crit par":"adriengervet","Dur\u00e9e de lecture estim\u00e9e":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/asso.graie.org\/portail\/fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique\/#article","isPartOf":{"@id":"https:\/\/asso.graie.org\/portail\/fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique\/"},"author":{"name":"adriengervet","@id":"https:\/\/asso.graie.org\/portail\/#\/schema\/person\/6c6bb5a38c33b4501e4e8ce71aba5a8c"},"headline":"Fiche Technique Autosurveillance n\u00b08 : Mesurage d&rsquo;un d\u00e9bit en conduite pleine par un d\u00e9bitm\u00e8tre \u00e9lectromagn\u00e9tique","datePublished":"2014-09-08T10:36:44+00:00","dateModified":"2025-12-08T07:58:00+00:00","mainEntityOfPage":{"@id":"https:\/\/asso.graie.org\/portail\/fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique\/"},"wordCount":148,"publisher":{"@id":"https:\/\/asso.graie.org\/portail\/#organization"},"keywords":["autosurveillance","conduite","d\u00e9bitm\u00e8tre","m\u00e9trologie","r\u00e9seaux assainissement"],"articleSection":["Autosurveillance","Productions"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/asso.graie.org\/portail\/fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique\/","url":"https:\/\/asso.graie.org\/portail\/fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique\/","name":"Fiche Technique Autosurveillance n\u00b08 : Mesurage d'un d\u00e9bit en conduite pleine par un d\u00e9bitm\u00e8tre \u00e9lectromagn\u00e9tique | Graie","isPartOf":{"@id":"https:\/\/asso.graie.org\/portail\/#website"},"datePublished":"2014-09-08T10:36:44+00:00","dateModified":"2025-12-08T07:58:00+00:00","breadcrumb":{"@id":"https:\/\/asso.graie.org\/portail\/fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/asso.graie.org\/portail\/fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/asso.graie.org\/portail\/fiche-technique-n8-mesurage-dun-debit-conduite-pleine-debitmetre-electromagnetique\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/asso.graie.org\/portail\/"},{"@type":"ListItem","position":2,"name":"Fiche Technique Autosurveillance n\u00b08 : Mesurage d&rsquo;un d\u00e9bit en conduite pleine par un d\u00e9bitm\u00e8tre \u00e9lectromagn\u00e9tique"}]},{"@type":"WebSite","@id":"https:\/\/asso.graie.org\/portail\/#website","url":"https:\/\/asso.graie.org\/portail\/","name":"Graie","description":"P\u00f4le Eau et Territoires","publisher":{"@id":"https:\/\/asso.graie.org\/portail\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/asso.graie.org\/portail\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/asso.graie.org\/portail\/#organization","name":"Le Graie","url":"https:\/\/asso.graie.org\/portail\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/asso.graie.org\/portail\/#\/schema\/logo\/image\/","url":"https:\/\/asso.graie.org\/portail\/wp-content\/uploads\/2021\/12\/Logotype-Graie.png","contentUrl":"https:\/\/asso.graie.org\/portail\/wp-content\/uploads\/2021\/12\/Logotype-Graie.png","width":1890,"height":1181,"caption":"Le Graie"},"image":{"@id":"https:\/\/asso.graie.org\/portail\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/fr.linkedin.com\/company\/graie?trk=top_nav_home","https:\/\/www.youtube.com\/channel\/UCZQk0Tt7upYwERYNdDIZqLQ","https:\/\/twitter.com\/asso_graie"]},{"@type":"Person","@id":"https:\/\/asso.graie.org\/portail\/#\/schema\/person\/6c6bb5a38c33b4501e4e8ce71aba5a8c","name":"adriengervet","url":"https:\/\/asso.graie.org\/portail\/author\/adriengervet\/"}]}},"_links":{"self":[{"href":"https:\/\/asso.graie.org\/portail\/wp-json\/wp\/v2\/posts\/4570"}],"collection":[{"href":"https:\/\/asso.graie.org\/portail\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/asso.graie.org\/portail\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/asso.graie.org\/portail\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/asso.graie.org\/portail\/wp-json\/wp\/v2\/comments?post=4570"}],"version-history":[{"count":2,"href":"https:\/\/asso.graie.org\/portail\/wp-json\/wp\/v2\/posts\/4570\/revisions"}],"predecessor-version":[{"id":30076,"href":"https:\/\/asso.graie.org\/portail\/wp-json\/wp\/v2\/posts\/4570\/revisions\/30076"}],"wp:attachment":[{"href":"https:\/\/asso.graie.org\/portail\/wp-json\/wp\/v2\/media?parent=4570"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/asso.graie.org\/portail\/wp-json\/wp\/v2\/categories?post=4570"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/asso.graie.org\/portail\/wp-json\/wp\/v2\/tags?post=4570"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}